Poor optical stability of molecular dyes when used as absorbers in water-based tissue-simulating phantoms

2019

Biomedical optical systems and models can be easily validated by the use of tissue-simulating phantoms. They can consist of water-based turbid media which often include inks (India ink and molecular dyes) as absorbers. Optical stability of commonly exploited inks under the influence of light, pH changes and the addition of TiO2 and surfactant, was studied. We found that the exposure to ultraviolet and visible light can crucially affect the absorption properties of molecular dyes. On average, absorption peaks decreased by 47.3% in 150 exposure hours. Furthermore, dilution can affect ink’s pH and by that, its decay rate under light exposure. When TiO2 was added to the phantoms, all molecular …

Materials sciencesurfactantturbid media02 engineering and technologymedicine.disease_cause01 natural sciencesIndia ink010309 opticsPulmonary surfactant0103 physical sciencesmedicinetissue-simulating phantomsmolecular dyesoptical spectroscopySpectroscopyAbsorption (electromagnetic radiation)Inkwell021001 nanoscience & nanotechnology3. Good healthDilutionoptical stabilityChemical engineering:NATURAL SCIENCES::Physics::Atomic and molecular physics [Research Subject Categories]Photocatalysis0210 nano-technologyUltravioletVisible spectrum
researchProduct

A human post-mortem brain model for the standardization of multi-centre MRI studies

2015

Multi-centre MRI studies of the brain are essential for enrolling large and diverse patient cohorts, as required for the investigation of heterogeneous neurological and psychiatric diseases. However, the multi-site comparison of standard MRI data sets that are weighted with respect to tissue parameters such as the relaxation times (T1, T2) and proton density (PD) may be problematic, as signal intensities and image contrasts depend on site-specific details such as the sequences used, imaging parameters, and sensitivity profiles of the radiofrequency (RF) coils. Water or gel phantoms are frequently used for long-term and/or inter-site quality assessment. However, these phantoms hardly mimic t…

Models Anatomicmedicine.medical_specialtyNeurologyCognitive NeuroscienceModels NeurologicalMulti-centre MRI studies; Post-mortem brain; Quantitative MRI; Standardization; Aged; Artifacts; Brain; Female; Humans; Magnetic Resonance Imaging; Multicenter Studies as Topic; Phantoms Imaging; Reproducibility of Results; Models Anatomic; Models Neurological; Postmortem Changes; Cognitive Neuroscience; Neurology; Medicine (all)Cognitive neuroscienceImaging phantomPhantomsImagingWhite matterModelsPost-mortem brainmedicineHumansMulticenter Studies as TopicMagnetization transferMulti-centre MRI studiesAgedmedicine.diagnostic_testbusiness.industryPhantoms ImagingMedicine (all)AnatomicBrainReproducibility of ResultsMagnetic resonance imagingHuman brainQuantitative MRIMagnetic Resonance ImagingStandardizationmedicine.anatomical_structureNeurologyPostmortem ChangesNeurologicalFemaleBrainstemNuclear medicinebusinessArtifacts
researchProduct

An enhanced random walk algorithm for delineation of head and neck cancers in PET studies

2017

An algorithm for delineating complex head and neck cancers in positron emission tomography (PET) images is presented in this article. An enhanced random walk (RW) algorithm with automatic seed detection is proposed and used to make the segmentation process feasible in the event of inhomogeneous lesions with bifurcations. In addition, an adaptive probability threshold and a k-means based clustering technique have been integrated in the proposed enhanced RW algorithm. The new threshold is capable of following the intensity changes between adjacent slices along the whole cancer volume, leading to an operator-independent algorithm. Validation experiments were first conducted on phantom studies:…

Similarity (geometry)Computer sciencePET imagingBiomedical EngineeringRandom walk030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicinemedicineImage Processing Computer-AssistedHumansSegmentationComputer visionCluster analysisEvent (probability theory)Settore ING-INF/05 - Sistemi Di Elaborazione Delle Informazionimedicine.diagnostic_testbusiness.industryPhantoms ImagingBiological target volume; Head and neck cancer segmentation; PET imaging; Random walksComputer Science ApplicationPattern recognitionRandom walkComputer Science ApplicationsBiological target volumeHausdorff distancePositron emission tomographyHead and Neck Neoplasms030220 oncology & carcinogenesisPositron-Emission TomographyArtificial intelligenceHead and neck cancer segmentationComputer Vision and Pattern RecognitionbusinessAlgorithmsBiological target volume Head and neck cancer segmentation PET imaging Random walks Algorithms Head and Neck Neoplasms Humans Image Processing Computer-Assisted Phantoms Imaging Positron-Emission TomographyVolume (compression)
researchProduct

Introduction to coronary imaging with 64-slice computed tomography

2005

The aim of this article is to illustrate the main technical improvements in the last generation of 64-row CT scanners and the possible applications in coronary angiography. In particular, we describe the new physical components (X-ray tube-detectors system) and the general scan and reconstruction parameters. We then define the scan protocols for coronary angiography with the new generation of 64-row CT scanners to enable radiologists to perform a CT study on the basis of the diagnostic possibilities.

Time FactorsImaging Sensitivity and Specificity Stents Time Factors TomographyContrast MediaSensitivity and Specificity64-row CTElectrocardiographyHeart RateSpiral Computed TomographyImage Processing Computer-AssistedHumanstechnical improvementsCoronary Artery BypassPhantoms ImagingPatient SelectionAlgorithms Artifacts Contrast Media Coronary Angiography/instrumentation/*methods Coronary Artery Bypass Coronary Stenosis/*radiography Electrocardiography Heart Rate Humans Image Processing; Computer-Assisted Patient Selection Phantoms; Imaging Sensitivity and Specificity Stents Time Factors Tomography; Spiral Computed Tomography; X-Ray Computed/instrumentation/*methodsCoronary StenosisComputer-Assisted Patient Selection PhantomsX-Ray Computed/instrumentation/*methodstechnical improvements; 64-row CT; coronary angiographyComputer-Assisted Patient Selection PhantomStentsAlgorithms Artifacts Contrast Media Coronary Angiography/instrumentation/*methods Coronary Artery Bypass Coronary Stenosis/*radiography Electrocardiography Heart Rate Humans Image Processingcoronary angiographyArtifactsTomography X-Ray ComputedTomography Spiral ComputedAlgorithms